This study presents an innovative and cost-effective approach for the structural health monitoring (SHM) of cable-stayed bridges, exploiting load-cell measurements on the stay cables for both static force monitoring and vibration-based dynamic assessment of the whole structure. By capturing high-frequency force fluctuations, load cells serve a dual purpose: (i) monitoring variations in axial cable forces and (ii) identifying the bridge’s dynamic properties through Operational Modal Analysis (OMA). This strategy enables a reduction in the number of sensors typically required—such as accelerometers installed on the deck—thereby simplifying both the monitoring system architecture and data management. A key feature of the proposed method is the introduction of an optimal sensor placement (OSP) algorithm, designed to identify the most informative stay cables to be instrumented, thus maximizing monitoring efficiency. The methodology is validated through a real-world application on a recently constructed cable-stayed bridge in central Italy, equipped with a comprehensive monitoring system. Data collected over nearly three years are used to compare modal parameters identified from load-cell measurements with those obtained from deck-mounted accelerometers. Results confirm the reliability and accuracy of the load-cell-based approach, highlighting its strong potential for the development of SHM systems for cable-stayed bridges.

Potential of Load Cells in the Static and Dynamic Monitoring of Cable-Stayed Bridges / Nicoletti, V., Quarchioni, S., Carbonari, S., Gara, F.. - In: PROCEDIA STRUCTURAL INTEGRITY. - ISSN 2452-3216. - 84:(2026), pp. 638-644. (3rd Fabre Conference: Existing Bridges, Viaducts, and Tunnels: Research, Innovation, and Applications, 2026 ita 2026) [10.1016/j.prostr.2026.06.082].

Potential of Load Cells in the Static and Dynamic Monitoring of Cable-Stayed Bridges

Nicoletti V.
Primo
;
Quarchioni S.;Carbonari S.;Gara F.
2026-01-01

Abstract

This study presents an innovative and cost-effective approach for the structural health monitoring (SHM) of cable-stayed bridges, exploiting load-cell measurements on the stay cables for both static force monitoring and vibration-based dynamic assessment of the whole structure. By capturing high-frequency force fluctuations, load cells serve a dual purpose: (i) monitoring variations in axial cable forces and (ii) identifying the bridge’s dynamic properties through Operational Modal Analysis (OMA). This strategy enables a reduction in the number of sensors typically required—such as accelerometers installed on the deck—thereby simplifying both the monitoring system architecture and data management. A key feature of the proposed method is the introduction of an optimal sensor placement (OSP) algorithm, designed to identify the most informative stay cables to be instrumented, thus maximizing monitoring efficiency. The methodology is validated through a real-world application on a recently constructed cable-stayed bridge in central Italy, equipped with a comprehensive monitoring system. Data collected over nearly three years are used to compare modal parameters identified from load-cell measurements with those obtained from deck-mounted accelerometers. Results confirm the reliability and accuracy of the load-cell-based approach, highlighting its strong potential for the development of SHM systems for cable-stayed bridges.
File in questo prodotto:
Non ci sono file associati a questo prodotto.

I documenti in IRIS sono protetti da copyright e tutti i diritti sono riservati, salvo diversa indicazione.

Utilizza questo identificativo per citare o creare un link a questo documento: https://hdl.handle.net/11566/367552
 Attenzione

Attenzione! I dati visualizzati non sono stati sottoposti a validazione da parte dell'ateneo

Citazioni
  • ???jsp.display-item.citation.pmc??? ND
  • Scopus 0
  • ???jsp.display-item.citation.isi??? ND
social impact