The successful application of finite difference time domain (FD-TD) methods to millimetric planar transmission lines presupposes a satisfactory answer to the problem of infinite line termination (absorbing boundary condition) in the presence of high frequency dispersion. A technique is proposed that reduces residual reflection to less than 1% for microstrip and coplanar line circuits up to and beyond 50 GHz. Four examples, two in microstrip, two in coplanar waveguide, are discussed.
FD-TD analysis of planar millimetric circuits / Moglie, F., Rozzi, T., Manini, M., Severini, R.. - ELETTRONICO. - (1993), pp. 394599.25-394599.28. (2nd IEEE Topical Meeting on Electrical Performance of Electronic Packaging, EPEP 1993 Monterey, CA, USA 20-22 October 1993) [10.1109/EPEP.1993.394599].
FD-TD analysis of planar millimetric circuits
Moglie F.
Primo
Writing – Original Draft Preparation
;Rozzi T.Ultimo
Writing – Review & Editing
;
1993-01-01
Abstract
The successful application of finite difference time domain (FD-TD) methods to millimetric planar transmission lines presupposes a satisfactory answer to the problem of infinite line termination (absorbing boundary condition) in the presence of high frequency dispersion. A technique is proposed that reduces residual reflection to less than 1% for microstrip and coplanar line circuits up to and beyond 50 GHz. Four examples, two in microstrip, two in coplanar waveguide, are discussed.I documenti in IRIS sono protetti da copyright e tutti i diritti sono riservati, salvo diversa indicazione.