This study presents the structural assessment of the Church of Santa Maria di Piazza in Ostra Vetere (Marche, Italy), severely damaged during the 2016 Central Italy earthquake sequence. The church required a detailed structural investigation to support the development of appropriate conservation strategies. Architecturally, the building combines Neo-Gothic and Romanesque elements, reflecting its complex historical evolution. The vertical emphasis of the dome and bell tower contrasts with the Romanesque brick façade, while the interior layout features three naves separated by pointed arches. The current structure dates to the early twentieth century, following the reconstruction of a partially destroyed seventeenth-century church. A distinctive feature is the use of reinforced concrete in the dome and bell tower spire, an innovative solution for the period when reinforced concrete was still emerging in structural practice. This early application introduces specific conservation challenges due to its different mechanical behaviour compared to traditional masonry. The study focuses on the investigation procedures adopted to evaluate the structural condition of the church, with particular attention to the dome and bell tower, which play a crucial role in both architectural expression and structural performance. The results contribute to the assessment and conservation of heritage structures incorporating early reinforced concrete elements, particularly in seismic-prone regions.
Integrated Structural Assessment and Conservation Strategy for the Church of Santa Maria di Piazza in Ostra Vetere (Italy) / Monni, F., Clementi, F., Schiavoni, M.. - STAMPA. - (2026), pp. 6-10. (2026 IEEE International Workshop on Metrology for Living Environment, MetroLivEnv 2026 University of Cambridge, UK 2026) [10.1109/MetroLivEnv70468.2026.11659899].
Integrated Structural Assessment and Conservation Strategy for the Church of Santa Maria di Piazza in Ostra Vetere (Italy)
Monni F.Membro del Collaboration Group
;Clementi F.
Membro del Collaboration Group
;Schiavoni M.Membro del Collaboration Group
2026-01-01
Abstract
This study presents the structural assessment of the Church of Santa Maria di Piazza in Ostra Vetere (Marche, Italy), severely damaged during the 2016 Central Italy earthquake sequence. The church required a detailed structural investigation to support the development of appropriate conservation strategies. Architecturally, the building combines Neo-Gothic and Romanesque elements, reflecting its complex historical evolution. The vertical emphasis of the dome and bell tower contrasts with the Romanesque brick façade, while the interior layout features three naves separated by pointed arches. The current structure dates to the early twentieth century, following the reconstruction of a partially destroyed seventeenth-century church. A distinctive feature is the use of reinforced concrete in the dome and bell tower spire, an innovative solution for the period when reinforced concrete was still emerging in structural practice. This early application introduces specific conservation challenges due to its different mechanical behaviour compared to traditional masonry. The study focuses on the investigation procedures adopted to evaluate the structural condition of the church, with particular attention to the dome and bell tower, which play a crucial role in both architectural expression and structural performance. The results contribute to the assessment and conservation of heritage structures incorporating early reinforced concrete elements, particularly in seismic-prone regions.I documenti in IRIS sono protetti da copyright e tutti i diritti sono riservati, salvo diversa indicazione.