The Generalized Thru-Reflect-Line (GTRL) calibration technique was originally developed for multi-mode waveguides. This work explored the GTRL technique for single-tier calibration of on-wafer two-port measurement of a Grounded Coplanar Waveguide (GCPW) transmission line. The GCPW, fabricated on 50-μm-thick SiC, is intrinsically a single-mode device. In this case, the GTRL technique was found comparable to the conventional two-tier LRRM + TRL technique in calibrating the single-sweep ultra-wideband measurement from 1 to 170 GHz. Above 170 GHz, both techniques fail to capture the suck out due to direct probe-probe crosstalk. Nevertheless, this shows that the GTRL technique can at least converges for a single-mode device. It remains to be proven that by accounting for probe-probe crosstalk, the GTRL technique can better handle the GCPW when it becomes multimode.

Generalized Thru-Reflect-Line Calibration for 1-220-GHz Single-Sweep Ultra-Wideband On-Wafer Measurement / Morini, A., Farina, M., Al Hadi, R., Li, T., Tong, X., Li, L., Hwang, J.C.M.. - (2026), pp. 386-389. (2026 IEEE MTT-S Radio Frequency Systems and Applications Symposium, IMS RFSA 2026 Boston, MA, USA 7 - 12 June 2026) [10.1109/IMSRFSA70221.2026.11624313].

Generalized Thru-Reflect-Line Calibration for 1-220-GHz Single-Sweep Ultra-Wideband On-Wafer Measurement

Morini A.
Primo
;
Farina M.
;
2026-01-01

Abstract

The Generalized Thru-Reflect-Line (GTRL) calibration technique was originally developed for multi-mode waveguides. This work explored the GTRL technique for single-tier calibration of on-wafer two-port measurement of a Grounded Coplanar Waveguide (GCPW) transmission line. The GCPW, fabricated on 50-μm-thick SiC, is intrinsically a single-mode device. In this case, the GTRL technique was found comparable to the conventional two-tier LRRM + TRL technique in calibrating the single-sweep ultra-wideband measurement from 1 to 170 GHz. Above 170 GHz, both techniques fail to capture the suck out due to direct probe-probe crosstalk. Nevertheless, this shows that the GTRL technique can at least converges for a single-mode device. It remains to be proven that by accounting for probe-probe crosstalk, the GTRL technique can better handle the GCPW when it becomes multimode.
2026
9798331547684
File in questo prodotto:
File Dimensione Formato  
Morini_Generalized-Thru-Reflect-Line-Calibration_2026.pdf

Solo gestori archivio

Tipologia: Versione editoriale (versione pubblicata con il layout dell'editore)
Licenza d'uso: Tutti i diritti riservati
Dimensione 1.31 MB
Formato Adobe PDF
1.31 MB Adobe PDF   Visualizza/Apri   Richiedi una copia

I documenti in IRIS sono protetti da copyright e tutti i diritti sono riservati, salvo diversa indicazione.

Utilizza questo identificativo per citare o creare un link a questo documento: https://hdl.handle.net/11566/364472
Citazioni
  • ???jsp.display-item.citation.pmc??? ND
  • Scopus 0
  • ???jsp.display-item.citation.isi??? ND
social impact