Buildings with complex geometry are very often a challenge in the process of dynamic identification since they are characterized by many vibration modes, sometimes even too closely-spaced to be clearly identified. Such modes may be difficult to distinguish in modal tests and lead to difficulties when they need to be automatically identified within the structural health monitoring framework. This work deals with the challenges faced for the dynamic identification through operational modal analyses of a complex hospital building. The whole building is composed by many structural bodies with the same height, same structural typology, and built in adjacent to each other, constituting a quite complex plan shape geometry. In the entire building, an intensive experimental campaign was made, and a spread dynamic seismic monitoring system has been installed to monitor the structure both during operational conditions and under extreme excitations, as, for instance, earthquakes.
Operational Modal Analysis of Complex Buildings with and Without Structural Joints / Nicoletti, V.; Quarchioni, S.; Tentella, L.; Amico, L.; Anna, B.; Gara, F.. - 514:(2024), pp. 720-727. (Intervento presentato al convegno 10th International Operational Modal Analysis Conference, IOMAC 2024 tenutosi a Naples, Italy nel 22 - 24 May 2024) [10.1007/978-3-031-61421-7_70].
Operational Modal Analysis of Complex Buildings with and Without Structural Joints
Nicoletti V.
;Tentella L.;Amico L.;Gara F.
2024-01-01
Abstract
Buildings with complex geometry are very often a challenge in the process of dynamic identification since they are characterized by many vibration modes, sometimes even too closely-spaced to be clearly identified. Such modes may be difficult to distinguish in modal tests and lead to difficulties when they need to be automatically identified within the structural health monitoring framework. This work deals with the challenges faced for the dynamic identification through operational modal analyses of a complex hospital building. The whole building is composed by many structural bodies with the same height, same structural typology, and built in adjacent to each other, constituting a quite complex plan shape geometry. In the entire building, an intensive experimental campaign was made, and a spread dynamic seismic monitoring system has been installed to monitor the structure both during operational conditions and under extreme excitations, as, for instance, earthquakes.File | Dimensione | Formato | |
---|---|---|---|
Articolo ospedale Torrette.pdf
Solo gestori archivio
Descrizione: Articolo negli atti
Tipologia:
Versione editoriale (versione pubblicata con il layout dell'editore)
Licenza d'uso:
Tutti i diritti riservati
Dimensione
3.12 MB
Formato
Adobe PDF
|
3.12 MB | Adobe PDF | Visualizza/Apri Richiedi una copia |
IOMAC2024 - Articolo Ospedale Torrette_Revised.pdf
embargo fino al 23/06/2025
Tipologia:
Documento in post-print (versione successiva alla peer review e accettata per la pubblicazione)
Licenza d'uso:
Tutti i diritti riservati
Dimensione
476.08 kB
Formato
Adobe PDF
|
476.08 kB | Adobe PDF | Visualizza/Apri Richiedi una copia |
I documenti in IRIS sono protetti da copyright e tutti i diritti sono riservati, salvo diversa indicazione.