Seismic events occurred in the last decade in Italy led the attention to the evaluation of the health and need of interventions on the existing school buildings heritage, whose collapse or loss in functionality after an earthquake may lead to significant economic and social losses. For this reason, this study focuses on the preliminary fragility assessment of a typical school r.c. frame building, retrofitted through an external configuration based on the use of fluid viscous dampers (FVDs). The case study is a two elevations moment resisting frame structure, built in Italy in the sixties without seismic code. The external retrofit configuration is a rocking base system consisting of a pinned-rocking braced frames equipped with fluid viscous dampers at their base. Fragility curves, built by accounting for different level of inter-storey drift and for seven intensity measures of the seismic action, provide useful insights about the efficiency and dynamic response of the r.c. frame before and after the retrofitting works.

Preliminary fragility analysis of a r.c. frame school building retrofitted by an external dissipative system / Gioiella, Laura; Ragni, Laura; Gara, Fabrizio; Dall’Asta, Andrea. - ELETTRONICO. - SS13:(2019), pp. 142-147. (Intervento presentato al convegno XVIII Convegno ANIDIS tenutosi a Ascoli Piceno nel 15-19 Settembre 2019).

Preliminary fragility analysis of a r.c. frame school building retrofitted by an external dissipative system

Laura Ragni;Fabrizio Gara;
2019-01-01

Abstract

Seismic events occurred in the last decade in Italy led the attention to the evaluation of the health and need of interventions on the existing school buildings heritage, whose collapse or loss in functionality after an earthquake may lead to significant economic and social losses. For this reason, this study focuses on the preliminary fragility assessment of a typical school r.c. frame building, retrofitted through an external configuration based on the use of fluid viscous dampers (FVDs). The case study is a two elevations moment resisting frame structure, built in Italy in the sixties without seismic code. The external retrofit configuration is a rocking base system consisting of a pinned-rocking braced frames equipped with fluid viscous dampers at their base. Fragility curves, built by accounting for different level of inter-storey drift and for seven intensity measures of the seismic action, provide useful insights about the efficiency and dynamic response of the r.c. frame before and after the retrofitting works.
2019
978-88-3339-256-1
File in questo prodotto:
Non ci sono file associati a questo prodotto.

I documenti in IRIS sono protetti da copyright e tutti i diritti sono riservati, salvo diversa indicazione.

Utilizza questo identificativo per citare o creare un link a questo documento: https://hdl.handle.net/11566/274077
 Attenzione

Attenzione! I dati visualizzati non sono stati sottoposti a validazione da parte dell'ateneo

Citazioni
  • ???jsp.display-item.citation.pmc??? ND
  • Scopus ND
  • ???jsp.display-item.citation.isi??? ND
social impact