Recurrence quantification analysis (RQA) allows the measurement of signal's regular and chaotic states using recurrence plots instead of deriving information purely from visual analysis. The current study presents RQA of multiple ECG time series simultaneously recorded through different electrodes and depicts the effect of motion artifacts through electrode synchronization and non-synchronization. The ECG data is acquired from a healthy 25-year-old male performing different exercise activities such as standing, walking and jumping. Also, the electrode in every recorded signal is placed at angle offset of 0°, 45° and 90°. The RQA analysis measures recurrence rate (RR), line entropy (ENT) and average diagonal length (L) reveal a highly stable and least chaotic signal in case of standing (RR=0.73, ENT=4.94, L=106.12), somewhat stable and a bit chaotic in case of walking (RR=0.75, ENT=5.35, L=129.13) and least stable and most chaotic in case of subject performing a jump (RR=0.61, ENT=5.07, L=99.16). Secondly, highest and second highest disturbances with respect to exercise movements are observed for electrode combinations (3, 4) and (1, 4). Distinguishing values for RQA-based measures for different exercise movements suggest that RQA is a powerful tool for differentiation of regular and irregular states occurring due to motion artifacts in the temporal patterns of ECG.

Recurrence Quantification Analysis for Motion Artifacts in Wearable ECG Sensors / Nasim, A.; Marcantoni, I.; Sbrollini, A.; Morettini, M.; Burattini, L.. - ELETTRONICO. - (2019), pp. 206-209. (Intervento presentato al convegno 23rd IEEE International Symposium on Consumer Technologies, ISCT 2019 tenutosi a ita nel 2019) [10.1109/ISCE.2019.8901002].

Recurrence Quantification Analysis for Motion Artifacts in Wearable ECG Sensors

Nasim A.;Marcantoni I.;Sbrollini A.;Morettini M.;Burattini L.
2019-01-01

Abstract

Recurrence quantification analysis (RQA) allows the measurement of signal's regular and chaotic states using recurrence plots instead of deriving information purely from visual analysis. The current study presents RQA of multiple ECG time series simultaneously recorded through different electrodes and depicts the effect of motion artifacts through electrode synchronization and non-synchronization. The ECG data is acquired from a healthy 25-year-old male performing different exercise activities such as standing, walking and jumping. Also, the electrode in every recorded signal is placed at angle offset of 0°, 45° and 90°. The RQA analysis measures recurrence rate (RR), line entropy (ENT) and average diagonal length (L) reveal a highly stable and least chaotic signal in case of standing (RR=0.73, ENT=4.94, L=106.12), somewhat stable and a bit chaotic in case of walking (RR=0.75, ENT=5.35, L=129.13) and least stable and most chaotic in case of subject performing a jump (RR=0.61, ENT=5.07, L=99.16). Secondly, highest and second highest disturbances with respect to exercise movements are observed for electrode combinations (3, 4) and (1, 4). Distinguishing values for RQA-based measures for different exercise movements suggest that RQA is a powerful tool for differentiation of regular and irregular states occurring due to motion artifacts in the temporal patterns of ECG.
2019
978-1-7281-3570-0
File in questo prodotto:
Non ci sono file associati a questo prodotto.

I documenti in IRIS sono protetti da copyright e tutti i diritti sono riservati, salvo diversa indicazione.

Utilizza questo identificativo per citare o creare un link a questo documento: https://hdl.handle.net/11566/272428
 Attenzione

Attenzione! I dati visualizzati non sono stati sottoposti a validazione da parte dell'ateneo

Citazioni
  • ???jsp.display-item.citation.pmc??? ND
  • Scopus 2
  • ???jsp.display-item.citation.isi??? 1
social impact