Background: Healthcare facilities (HF) represent an at-risk environment for legionellosis transmission occuring after inhaling aerosols produced from contaminated water sources. The control of water is preferred to that of air because to date there are not standardized protocols sampling. Methods: Legionella air contamination was investigated in the bathrooms of 11 HF contaminated with Legionella by active sampling (Surface Air System and Coriolis®?) and passive sampling. During the 8-hour sampling, hot tap water was sampled three times and analyzed for Legionella. Air samples were evaluated using culture based methods, whereas liquid samples collected using the Coriolis©? were also analyzed by real-time PCR. Legionella presence in air and water was compared by sequence-based typing (SBT) methods. Results: Air contamination was found in four HF (36.4%) by at least one of the culturable methods. The culturable investigation by Coriolis did not yield Legionella. However, molecular investigation using Coriolis resulted in eight HF being positive for Legionella in air, which was greater than the number of positives obtained by culturable methods.

A Multicenter Study on Legionella Air Contamination in Italian Healthcare Facilities: Comparison of Different Sampling Methods / Nullo, nullDe Giglio; Montagna M., T.; Diella, G.; Divenuto, F; Pacifico, C.; Rutigliano, S.; Cristina M., L.; Napoli, C.; Agodi, A.; Baldovin, T.; Casini, B.; D'Errico, Marcello Mario; Delia A., S.; Deriu M., G.; Guida M. Laganà P., Liguori G.; Moro, M.; Mura, I.; Pennino, F; Privitela, G.; Nullv, nullRomano Spica; Sembeni, S.; Spagnolo A., M.; Tardivo, S.; Valeriani, F; Albertini, R.; Pasquarella, C.. - (2017). (Intervento presentato al convegno The 9th International Conference on Legionella tenutosi a Roma nel 26-30 settembre 2017).

A Multicenter Study on Legionella Air Contamination in Italian Healthcare Facilities: Comparison of Different Sampling Methods

D'ERRICO, Marcello Mario;
2017-01-01

Abstract

Background: Healthcare facilities (HF) represent an at-risk environment for legionellosis transmission occuring after inhaling aerosols produced from contaminated water sources. The control of water is preferred to that of air because to date there are not standardized protocols sampling. Methods: Legionella air contamination was investigated in the bathrooms of 11 HF contaminated with Legionella by active sampling (Surface Air System and Coriolis®?) and passive sampling. During the 8-hour sampling, hot tap water was sampled three times and analyzed for Legionella. Air samples were evaluated using culture based methods, whereas liquid samples collected using the Coriolis©? were also analyzed by real-time PCR. Legionella presence in air and water was compared by sequence-based typing (SBT) methods. Results: Air contamination was found in four HF (36.4%) by at least one of the culturable methods. The culturable investigation by Coriolis did not yield Legionella. However, molecular investigation using Coriolis resulted in eight HF being positive for Legionella in air, which was greater than the number of positives obtained by culturable methods.
2017
File in questo prodotto:
Non ci sono file associati a questo prodotto.

I documenti in IRIS sono protetti da copyright e tutti i diritti sono riservati, salvo diversa indicazione.

Utilizza questo identificativo per citare o creare un link a questo documento: https://hdl.handle.net/11566/251310
 Attenzione

Attenzione! I dati visualizzati non sono stati sottoposti a validazione da parte dell'ateneo

Citazioni
  • ???jsp.display-item.citation.pmc??? ND
  • Scopus ND
  • ???jsp.display-item.citation.isi??? ND
social impact