Electrocardiographic (ECG) signal presents many clinically relevant features (e. g. QT-interval, that is the duration of the ventricular depolarization). A novel processing technique has been demonstrated to be capable to measure some important characteristics according to the morphology of the waveform. Basing on that, the aim of this work is to propose an improved algorithm and to prove its efficacy in the assessment of the subject's Heart Rate (HR) in comparison to standard algorithms (i.e. Pan & Tompkins). Results obtained in experimentally collected ECG signals for the identification of the main feature (R-peak) are comparable to those obtained with the traditional approach (sensitivity of 99.55% and 99.95%, respectively). Moreover, the use of this algorithm has been broaden to signals coming from different biomedical sensors (based on optical, acoustical and mechanical principles), all related to blood flow, for the computation of HR. In particular, it has been employed to PCG (Phonocardiography), PPG (Photoplethysmography) and VCG (Vibrocardiography), where standard algorithms could not be widely applied. HR results from a measurement campaign on 8 healthy subjects have shown, with respect to ECG, deviations (calculated as 2 sigma) of +/- 3.3 bpm, +/- 2.3 bpm and +/- 1.5 bpm for PCG, PPG and VCG, respectively. In conclusion, it is possible to state that the adopted algorithm is able to measure HR accurately from different biosignals. Future work will involve the extraction of additional morphological features in order to characterise the waveforms more deeply and to better describe the subject's health status.

Heart Rate assessment by means of a novel approach applied to signals of different nature / Cosoli, G; Casacanditella, L.; Tomasini, Enrico Primo; Scalise, Lorenzo. - In: JOURNAL OF PHYSICS. CONFERENCE SERIES. - ISSN 1742-6588. - ELETTRONICO. - 778:(2017), p. 012001. (Intervento presentato al convegno 23rd AIVELA Annual Meeting 2015 tenutosi a ita nel 2015) [10.1088/1742-6596/778/1/012001].

Heart Rate assessment by means of a novel approach applied to signals of different nature

Cosoli, G;TOMASINI, Enrico Primo;SCALISE, Lorenzo
2017-01-01

Abstract

Electrocardiographic (ECG) signal presents many clinically relevant features (e. g. QT-interval, that is the duration of the ventricular depolarization). A novel processing technique has been demonstrated to be capable to measure some important characteristics according to the morphology of the waveform. Basing on that, the aim of this work is to propose an improved algorithm and to prove its efficacy in the assessment of the subject's Heart Rate (HR) in comparison to standard algorithms (i.e. Pan & Tompkins). Results obtained in experimentally collected ECG signals for the identification of the main feature (R-peak) are comparable to those obtained with the traditional approach (sensitivity of 99.55% and 99.95%, respectively). Moreover, the use of this algorithm has been broaden to signals coming from different biomedical sensors (based on optical, acoustical and mechanical principles), all related to blood flow, for the computation of HR. In particular, it has been employed to PCG (Phonocardiography), PPG (Photoplethysmography) and VCG (Vibrocardiography), where standard algorithms could not be widely applied. HR results from a measurement campaign on 8 healthy subjects have shown, with respect to ECG, deviations (calculated as 2 sigma) of +/- 3.3 bpm, +/- 2.3 bpm and +/- 1.5 bpm for PCG, PPG and VCG, respectively. In conclusion, it is possible to state that the adopted algorithm is able to measure HR accurately from different biosignals. Future work will involve the extraction of additional morphological features in order to characterise the waveforms more deeply and to better describe the subject's health status.
2017
23rd Annual Meeting of the Italian-Association-of-Laser-Velocimetry-and-Non-Invasive-Diagnostics (AIVELA)
File in questo prodotto:
Non ci sono file associati a questo prodotto.

I documenti in IRIS sono protetti da copyright e tutti i diritti sono riservati, salvo diversa indicazione.

Utilizza questo identificativo per citare o creare un link a questo documento: https://hdl.handle.net/11566/248842
 Attenzione

Attenzione! I dati visualizzati non sono stati sottoposti a validazione da parte dell'ateneo

Citazioni
  • ???jsp.display-item.citation.pmc??? ND
  • Scopus 12
  • ???jsp.display-item.citation.isi??? 9
social impact