The external blood pressure pulse, recorded on a non-contact basis using the method of laser Doppler vibrometry (LDV), has been shown to be a rich source of information regarding cardiac and vascular dynamics. Considerable attention has been directed specifically to the pulse from the neck, overlying the carotid artery, which is of special interest because the carotid pulse is highly similar to the central aortic pressure pulse. The findings presented here are consistent with an interpretation of the signal at the neck as originating in the carotid artery. A detailed mapping study involving a 35 point matrix over the right neck disclosed a focal zone of maximal signal amplitude, with a course consistent with the tract of the underlying carotid. Appreciable individual differences in the 22 examinees were disclosed, particularly at lower sites. In addition to confirming a local source for the LDV carotid pulse, the data highlight the importance of accurate targeting considerations.

LDV arterial pulse signal: Evidence for local generation in the carotid / Casaccia, Sara; Sirevaag, Erik J.; Richter, Edward J.; Casacanditella, Luigi; Scalise, Lorenzo; Rohrbaugh, John W.. - ELETTRONICO. - 1740:(2016), p. 050008. (Intervento presentato al convegno 12th International A.I.VE.LA. Conference on Vibration Measurements by Laser and Noncontact Techniques: Advances and Applications tenutosi a ita nel 2016) [10.1063/1.4952672].

LDV arterial pulse signal: Evidence for local generation in the carotid

Casaccia, Sara;SCALISE, Lorenzo;
2016-01-01

Abstract

The external blood pressure pulse, recorded on a non-contact basis using the method of laser Doppler vibrometry (LDV), has been shown to be a rich source of information regarding cardiac and vascular dynamics. Considerable attention has been directed specifically to the pulse from the neck, overlying the carotid artery, which is of special interest because the carotid pulse is highly similar to the central aortic pressure pulse. The findings presented here are consistent with an interpretation of the signal at the neck as originating in the carotid artery. A detailed mapping study involving a 35 point matrix over the right neck disclosed a focal zone of maximal signal amplitude, with a course consistent with the tract of the underlying carotid. Appreciable individual differences in the 22 examinees were disclosed, particularly at lower sites. In addition to confirming a local source for the LDV carotid pulse, the data highlight the importance of accurate targeting considerations.
2016
AIP Conference Proceedings
9780735413979
File in questo prodotto:
Non ci sono file associati a questo prodotto.

I documenti in IRIS sono protetti da copyright e tutti i diritti sono riservati, salvo diversa indicazione.

Utilizza questo identificativo per citare o creare un link a questo documento: https://hdl.handle.net/11566/248763
 Attenzione

Attenzione! I dati visualizzati non sono stati sottoposti a validazione da parte dell'ateneo

Citazioni
  • ???jsp.display-item.citation.pmc??? ND
  • Scopus 3
  • ???jsp.display-item.citation.isi??? 3
social impact