T-wave alternans, qualitatively defined as every-otherbeat alternations of the T-wave morphology, has no standardized quantitative definition yet. Differences in quantitative information provided by the fast-Fouriertransform spectral method (FFTSM), the modifiedmoving- average method (MMAM), and our heart-rate adaptive match filter method (AMFM) were analyzed here making use of two synthetic ECG tracings with stationary TWA: triangular the first (TRI_TWA), with Twaves maximum-amplitude difference (AMAX) of 100 mu V and mean-amplitude difference (AMEAN) of 50 mu V; and uniform the second (UNI_TWA), with A(MAX)= A(MEAN)= 100 mu V. Application of FFTSM, MMAM, and AMFM to TRI_TWA yielded 57 mu V, 100 mu V, and 50 mu V TWA amplitude estimation, respectively. Instead, 100 mu V TWA amplitude was provided by each method after their application to UNI_TWA. Thus, FFTSM and AMFM provide estimates of AMEAN, while MMAM of AMAX.

T-Wave Alternans Quantification: Which Information from Different Methods? / Burattini, Laura; Bini, S; Burattini, Roberto. - In: COMPUTING IN CARDIOLOGY. - ISSN 2325-8861. - ELETTRONICO. - 37:(2010), pp. 1043-1046. (Intervento presentato al convegno Computing in Cardiology tenutosi a Belfast, Ireland nel 26-29 September, 2010).

T-Wave Alternans Quantification: Which Information from Different Methods?

BURATTINI, LAURA;BURATTINI, ROBERTO
2010-01-01

Abstract

T-wave alternans, qualitatively defined as every-otherbeat alternations of the T-wave morphology, has no standardized quantitative definition yet. Differences in quantitative information provided by the fast-Fouriertransform spectral method (FFTSM), the modifiedmoving- average method (MMAM), and our heart-rate adaptive match filter method (AMFM) were analyzed here making use of two synthetic ECG tracings with stationary TWA: triangular the first (TRI_TWA), with Twaves maximum-amplitude difference (AMAX) of 100 mu V and mean-amplitude difference (AMEAN) of 50 mu V; and uniform the second (UNI_TWA), with A(MAX)= A(MEAN)= 100 mu V. Application of FFTSM, MMAM, and AMFM to TRI_TWA yielded 57 mu V, 100 mu V, and 50 mu V TWA amplitude estimation, respectively. Instead, 100 mu V TWA amplitude was provided by each method after their application to UNI_TWA. Thus, FFTSM and AMFM provide estimates of AMEAN, while MMAM of AMAX.
2010
978-1-4244-7318-2
File in questo prodotto:
Non ci sono file associati a questo prodotto.

I documenti in IRIS sono protetti da copyright e tutti i diritti sono riservati, salvo diversa indicazione.

Utilizza questo identificativo per citare o creare un link a questo documento: https://hdl.handle.net/11566/48569
 Attenzione

Attenzione! I dati visualizzati non sono stati sottoposti a validazione da parte dell'ateneo

Citazioni
  • ???jsp.display-item.citation.pmc??? ND
  • Scopus 3
  • ???jsp.display-item.citation.isi??? 1
social impact