Neat SC-CO(2) extraction was compared with the conventional Folch and the Bligh and Dyer (B&D) extraction, as a sample preparation technique for the determination of cholesterol oxidation products (COPS) in spray-dried egg yolk. Total lipids could be extracted in analytical scale (2 g sample) using four dynamic extraction steps of 30 min each, at 40 degreesC and 51,700 kPa. The recovery of total COPs in the SC-CO(2) extract (35 mug COPs g(-1) extract) was not statistically different with respect to the Folch and B&D extract. SC-CO(2) extraction showed important advantages, such as the elimination of chlorinated solvents and the reduction of sample manipulation and preparation time. The formation of artifacts of COPS due to the acidic properties of CO(2) during the sample preparation did not reach a significant extent.

Determination of cholesterol oxidation products in the supercritical carbon dioxide extract of egg yolk powder: Comparison with conventional liquid solvent extraction methods / Boselli, Emanuele; M., Bonoli; M. F., Caboni; G., Lercker. - In: EUROPEAN FOOD RESEARCH AND TECHNOLOGY. - ISSN 1438-2377. - 215:(2002), pp. 72-75. [10.1007/s00217-002-0522-1]

Determination of cholesterol oxidation products in the supercritical carbon dioxide extract of egg yolk powder: Comparison with conventional liquid solvent extraction methods

BOSELLI, EMANUELE;
2002-01-01

Abstract

Neat SC-CO(2) extraction was compared with the conventional Folch and the Bligh and Dyer (B&D) extraction, as a sample preparation technique for the determination of cholesterol oxidation products (COPS) in spray-dried egg yolk. Total lipids could be extracted in analytical scale (2 g sample) using four dynamic extraction steps of 30 min each, at 40 degreesC and 51,700 kPa. The recovery of total COPs in the SC-CO(2) extract (35 mug COPs g(-1) extract) was not statistically different with respect to the Folch and B&D extract. SC-CO(2) extraction showed important advantages, such as the elimination of chlorinated solvents and the reduction of sample manipulation and preparation time. The formation of artifacts of COPS due to the acidic properties of CO(2) during the sample preparation did not reach a significant extent.
2002
File in questo prodotto:
Non ci sono file associati a questo prodotto.

I documenti in IRIS sono protetti da copyright e tutti i diritti sono riservati, salvo diversa indicazione.

Utilizza questo identificativo per citare o creare un link a questo documento: https://hdl.handle.net/11566/35604
 Attenzione

Attenzione! I dati visualizzati non sono stati sottoposti a validazione da parte dell'ateneo

Citazioni
  • ???jsp.display-item.citation.pmc??? ND
  • Scopus 9
  • ???jsp.display-item.citation.isi??? 7
social impact