Increasing the signal-to-noise ratio in dynamic atomic force microscopy plays a key role in nanomechanical mapping of materials with atomic resolution. In this work, we develop an experimental procedure for increasing the sensitivity of higher harmonics of an atomic-force-microscope cantilever without modifying the cantilever geometry but instead by utilizing dynamical mode coupling between its flexural modes of vibration. We perform experiments on different cantilevers and samples and observe that via nonlinear resonance frequency tuning we can obtain a frequency range where strong modal interactions lead to 7-fold and 16-fold increases in the sensitivity of the 6th and 17th harmonics while reducing sample indentation. We derive a numerical model that captures the observed physics and confirms that nonlinear mode coupling is the reason for the increase of the amplitude of higher harmonics during tip-sample interactions.

Mode Coupling in Dynamic Atomic Force Microscopy / Chandrashekar, A.; Belardinelli, P.; Lenci, S.; Staufer, U.; Alijani, F.. - In: PHYSICAL REVIEW APPLIED. - ISSN 2331-7019. - STAMPA. - 15:2(2021). [10.1103/PhysRevApplied.15.024013]

Mode Coupling in Dynamic Atomic Force Microscopy

Belardinelli P.;Lenci S.;
2021-01-01

Abstract

Increasing the signal-to-noise ratio in dynamic atomic force microscopy plays a key role in nanomechanical mapping of materials with atomic resolution. In this work, we develop an experimental procedure for increasing the sensitivity of higher harmonics of an atomic-force-microscope cantilever without modifying the cantilever geometry but instead by utilizing dynamical mode coupling between its flexural modes of vibration. We perform experiments on different cantilevers and samples and observe that via nonlinear resonance frequency tuning we can obtain a frequency range where strong modal interactions lead to 7-fold and 16-fold increases in the sensitivity of the 6th and 17th harmonics while reducing sample indentation. We derive a numerical model that captures the observed physics and confirms that nonlinear mode coupling is the reason for the increase of the amplitude of higher harmonics during tip-sample interactions.
2021
File in questo prodotto:
Non ci sono file associati a questo prodotto.

I documenti in IRIS sono protetti da copyright e tutti i diritti sono riservati, salvo diversa indicazione.

Utilizza questo identificativo per citare o creare un link a questo documento: https://hdl.handle.net/11566/288570
 Attenzione

Attenzione! I dati visualizzati non sono stati sottoposti a validazione da parte dell'ateneo

Citazioni
  • ???jsp.display-item.citation.pmc??? ND
  • Scopus 7
  • ???jsp.display-item.citation.isi??? 7
social impact