The paper presents the results of an experimental campaign aimed at investigating the in-plane and out-of-plane behavior of tuff and fired clay brick masonry panels reinforced by a commercial, not yet tested, Textile Reinforced Mortar (TRM) system. The TRM, consisting of hydraulic lime mortar coupled with a bidirectional glass fabric (total thickness of 30 mm), was applied on both sides of the panels and connected through stainless-steel helical bars. First, a mechanical characterization of the TRM system was carried out, according to recent guidelines (AC434 and CNR-DT215) by means of tensile tests and single-shear bond tests on the two different substrates. Then, the effectiveness of the reinforcement was investigated through uniaxial compression, diagonal compression and three-point bending tests on masonry panels. After that, experimental results were compared to the predictions of recent guidelines and analytical models available in the literature, by using the mechanical parameters obtained from the TRM mechanical characterization. TRM showed to be very effective in increasing the in-plane shear strength of tuff panels, of about 170%, whereas in the case of fired clay brick ones the increase was limited to 33%. Besides, the diagonal compression strength of reinforced specimens seemed to be strongly influenced by the mortar matrix, instead of by the fabric reinforcement, as it usually happens i.e. for Fabric Reinforced Cementitious Matrix (FRCM) systems. Thus, novel simplified analytical formulations to predict the shear strength of reinforced panels by only considering the contribution of the TRM matrix were provided, discussed and compared to current analytical approaches for FRCM systems. As regards the out-of-plane behavior, the TRM system significantly increased the out-of-plane bending strength and ductility of both tuff and fired clay brick panels. The applicability of current analytical approaches, as well as possible amendments, was also investigated. Finally, the compressive behavior of the walls was not substantially modified by the reinforcement, reasonably due to the low axial stiffness of the connectors and, to a minor extent, because they were dry inserted within the masonry and simply folded over the glass fabric.

TRM reinforced tuff and fired clay brick masonry: Experimental and analytical investigation on their in-plane and out-of-plane behavior / Donnini, J.; Maracchini, G.; Lenci, S.; Corinaldesi, V.; Quagliarini, E.. - In: CONSTRUCTION AND BUILDING MATERIALS. - ISSN 0950-0618. - STAMPA. - 272:(2021), p. 121643. [10.1016/j.conbuildmat.2020.121643]

TRM reinforced tuff and fired clay brick masonry: Experimental and analytical investigation on their in-plane and out-of-plane behavior

Donnini J.;Maracchini G.;Lenci S.;Corinaldesi V.;Quagliarini E.
2021-01-01

Abstract

The paper presents the results of an experimental campaign aimed at investigating the in-plane and out-of-plane behavior of tuff and fired clay brick masonry panels reinforced by a commercial, not yet tested, Textile Reinforced Mortar (TRM) system. The TRM, consisting of hydraulic lime mortar coupled with a bidirectional glass fabric (total thickness of 30 mm), was applied on both sides of the panels and connected through stainless-steel helical bars. First, a mechanical characterization of the TRM system was carried out, according to recent guidelines (AC434 and CNR-DT215) by means of tensile tests and single-shear bond tests on the two different substrates. Then, the effectiveness of the reinforcement was investigated through uniaxial compression, diagonal compression and three-point bending tests on masonry panels. After that, experimental results were compared to the predictions of recent guidelines and analytical models available in the literature, by using the mechanical parameters obtained from the TRM mechanical characterization. TRM showed to be very effective in increasing the in-plane shear strength of tuff panels, of about 170%, whereas in the case of fired clay brick ones the increase was limited to 33%. Besides, the diagonal compression strength of reinforced specimens seemed to be strongly influenced by the mortar matrix, instead of by the fabric reinforcement, as it usually happens i.e. for Fabric Reinforced Cementitious Matrix (FRCM) systems. Thus, novel simplified analytical formulations to predict the shear strength of reinforced panels by only considering the contribution of the TRM matrix were provided, discussed and compared to current analytical approaches for FRCM systems. As regards the out-of-plane behavior, the TRM system significantly increased the out-of-plane bending strength and ductility of both tuff and fired clay brick panels. The applicability of current analytical approaches, as well as possible amendments, was also investigated. Finally, the compressive behavior of the walls was not substantially modified by the reinforcement, reasonably due to the low axial stiffness of the connectors and, to a minor extent, because they were dry inserted within the masonry and simply folded over the glass fabric.
2021
File in questo prodotto:
Non ci sono file associati a questo prodotto.

I documenti in IRIS sono protetti da copyright e tutti i diritti sono riservati, salvo diversa indicazione.

Utilizza questo identificativo per citare o creare un link a questo documento: https://hdl.handle.net/11566/287962
 Attenzione

Attenzione! I dati visualizzati non sono stati sottoposti a validazione da parte dell'ateneo

Citazioni
  • ???jsp.display-item.citation.pmc??? ND
  • Scopus 45
  • ???jsp.display-item.citation.isi??? 31
social impact