Surface electromyography (sEMG) recordings provide a safe, easy, and non-invasive method, allowing objective quantification of the electric activity of muscles. Analysis of sEMG plays an important diagnostic role in assessing muscle disorders. Typically, sEMG is a non-stationary signal contaminated by various noises or artifacts that originate at the skin-electrode interface, in the electronics, and in external sources. Thus, appropriate filtering procedures have to be applied to make sEMG clinically usable, in order to extract the main sEMG features. In the recent literatures, among the best performing denoising methods, Wavelet transformation (WT) denoising has been proposed. In particular, aim of this study is to propose a new denoising method based on WT multi-level decomposition analysis. To this aim, Daubechies mother wavelet (4th order, 9 levels of decomposition) was applied to 5 real sEMG tracings. Tibialis anterior (TA) and gastrocnemius lateralis (GL) signals are considered. This method focusses on the choice of a new thresholding rule for sEMG reconstruction and denoising. Performances of this method are computed against soft-thresholding denoising technique (ST) in terms of Root Mean Square Error (RMSE). After application of WT multi-level denoising technique, signal-to-noise ratio (SNR) increased significantly (TA: 14.5 ± 6.9 vs. 19.5 ± 7.1; GL: 14.0 ± 5.4 vs. 18.7 ± 6.3). Moreover, WT multi-level denoising technique showed a lower dispersion than ST (RMSE for TA: 0.8 vs. 1.2; RMSE for GL: 0.9 vs. 1.1.), introduced no sEMG signal delay. Thus, this method is a novel and efficient tool for sEMG denoising, that could be used to make easier the detection of sEMG activation onset-offset.

Wavelet Analysis-Based Reconstruction for sEMG Signal Denoising / Strazza, A.; Verdini, F.; Mengarelli, A.; Cardarelli, S.; Tigrini, A.; Fioretti, S.; Di Nardo, F.. - ELETTRONICO. - 76:(2020), pp. 245-252. (Intervento presentato al convegno 15th Mediterranean Conference on Medical and Biological Engineering and Computing, MEDICON 2019 tenutosi a prt nel 2019) [10.1007/978-3-030-31635-8_29].

Wavelet Analysis-Based Reconstruction for sEMG Signal Denoising

Strazza A.;Verdini F.;Mengarelli A.;Cardarelli S.;Tigrini A.;Fioretti S.;Di Nardo F.
2020-01-01

Abstract

Surface electromyography (sEMG) recordings provide a safe, easy, and non-invasive method, allowing objective quantification of the electric activity of muscles. Analysis of sEMG plays an important diagnostic role in assessing muscle disorders. Typically, sEMG is a non-stationary signal contaminated by various noises or artifacts that originate at the skin-electrode interface, in the electronics, and in external sources. Thus, appropriate filtering procedures have to be applied to make sEMG clinically usable, in order to extract the main sEMG features. In the recent literatures, among the best performing denoising methods, Wavelet transformation (WT) denoising has been proposed. In particular, aim of this study is to propose a new denoising method based on WT multi-level decomposition analysis. To this aim, Daubechies mother wavelet (4th order, 9 levels of decomposition) was applied to 5 real sEMG tracings. Tibialis anterior (TA) and gastrocnemius lateralis (GL) signals are considered. This method focusses on the choice of a new thresholding rule for sEMG reconstruction and denoising. Performances of this method are computed against soft-thresholding denoising technique (ST) in terms of Root Mean Square Error (RMSE). After application of WT multi-level denoising technique, signal-to-noise ratio (SNR) increased significantly (TA: 14.5 ± 6.9 vs. 19.5 ± 7.1; GL: 14.0 ± 5.4 vs. 18.7 ± 6.3). Moreover, WT multi-level denoising technique showed a lower dispersion than ST (RMSE for TA: 0.8 vs. 1.2; RMSE for GL: 0.9 vs. 1.1.), introduced no sEMG signal delay. Thus, this method is a novel and efficient tool for sEMG denoising, that could be used to make easier the detection of sEMG activation onset-offset.
2020
978-3-030-31634-1
978-3-030-31635-8
File in questo prodotto:
Non ci sono file associati a questo prodotto.

I documenti in IRIS sono protetti da copyright e tutti i diritti sono riservati, salvo diversa indicazione.

Utilizza questo identificativo per citare o creare un link a questo documento: https://hdl.handle.net/11566/282797
 Attenzione

Attenzione! I dati visualizzati non sono stati sottoposti a validazione da parte dell'ateneo

Citazioni
  • ???jsp.display-item.citation.pmc??? ND
  • Scopus 2
  • ???jsp.display-item.citation.isi??? 2
social impact