Purpose: The aim of this study is to evaluate the feasibility of percutaneous lung tumor biopsy under cone beam-computed tomography (CBCT) with PET-CT imaging fusion. Materials and Methods: Eleven patients (four women and seven men) underwent C-arm CBCT lung biopsy with PET-CT fusion imaging. A preprocedural PET-CT scan was manually fused with procedural CBCT based on anatomical landmarks; using real-time fluoroscopy, the coregistered PET-CT and CBCT images were overlaid to guide the needle trajectory. Technical success, accuracy, sensibility and specificity were evaluated. Mean total procedure time and time required for image elaboration were recorded. Results: Technical success, diagnostic accuracy, sensitivity and specificity were 100%. The mean procedure time was 38 min. The average time of PET-CT/CBCT image fusion elaboration was 3.53 min for planning and 3.42 min for needle positioning check. Conclusion: CBCT-guided percutaneous lung biopsy with PET-CT fusion imaging is a feasible and effective procedure, with the potential to further improve diagnostic yield by targeting the most metabolically active portion of a lesion, whether it is morphologically altered or normal.

Percutaneous Lung Tumor Biopsy Under CBCT Guidance with PET-CT Fusion Imaging: Preliminary Experience / Floridi, C.; Carnevale, A.; Fumarola, E. M.; Schampaert, S.; Fontana, F.; De Palma, D.; Del Sole, A.; Giganti, M.; Carrafiello, G.. - In: CARDIOVASCULAR AND INTERVENTIONAL RADIOLOGY. - ISSN 0174-1551. - 42:11(2019), pp. 1644-1648. [10.1007/s00270-019-02270-1]

Percutaneous Lung Tumor Biopsy Under CBCT Guidance with PET-CT Fusion Imaging: Preliminary Experience

Floridi C.
;
2019-01-01

Abstract

Purpose: The aim of this study is to evaluate the feasibility of percutaneous lung tumor biopsy under cone beam-computed tomography (CBCT) with PET-CT imaging fusion. Materials and Methods: Eleven patients (four women and seven men) underwent C-arm CBCT lung biopsy with PET-CT fusion imaging. A preprocedural PET-CT scan was manually fused with procedural CBCT based on anatomical landmarks; using real-time fluoroscopy, the coregistered PET-CT and CBCT images were overlaid to guide the needle trajectory. Technical success, accuracy, sensibility and specificity were evaluated. Mean total procedure time and time required for image elaboration were recorded. Results: Technical success, diagnostic accuracy, sensitivity and specificity were 100%. The mean procedure time was 38 min. The average time of PET-CT/CBCT image fusion elaboration was 3.53 min for planning and 3.42 min for needle positioning check. Conclusion: CBCT-guided percutaneous lung biopsy with PET-CT fusion imaging is a feasible and effective procedure, with the potential to further improve diagnostic yield by targeting the most metabolically active portion of a lesion, whether it is morphologically altered or normal.
2019
File in questo prodotto:
Non ci sono file associati a questo prodotto.

I documenti in IRIS sono protetti da copyright e tutti i diritti sono riservati, salvo diversa indicazione.

Utilizza questo identificativo per citare o creare un link a questo documento: https://hdl.handle.net/11566/279715
 Attenzione

Attenzione! I dati visualizzati non sono stati sottoposti a validazione da parte dell'ateneo

Citazioni
  • ???jsp.display-item.citation.pmc??? 7
  • Scopus 14
  • ???jsp.display-item.citation.isi??? 13
social impact