The proposed dataset provides a complete set of simultaneously acquired data from contactless and wearable devices for direct and indirect heart-rate measurement. Data were acquired on a total of 20 healthy white Caucasian subjects wearing no makeup (10 males and 10 females; age: 22.50 ± 1.57 years; height: 173 ± 10 cm; weight: 62.80 ± 9.52 kg) and consisted of: i) videos of the subject's face acquired by a RGB-D (Red, Green, Blue and Depth) camera (Microsoft Kinect v2), which is a contactless device; ii) electrocardiographic (ECG) recordings acquired by a clinical Holter ECG recorder (Global Instrumentation's M12R Holter), which is a wearable device; and iii) heart-rate measurements acquired from a commercial smartwatch (Moto 360 smartwatch by Motorola), which is also a wearable device. ECG recordings were processed to extract the R-peaks position and obtain a reference indirect measurement of the heart rate. A direct measurement of the heart rate was provided by the commercial smartwatch. The dataset here presented could be useful to develop new algorithms for heart-rate detection from contactless devices and to validate contactless heart-rate estimation in comparison to reference heart rate from clinical wearable devices and to heart rate from commercial wearable devices.

Simultaneously acquired data from contactless and wearable devices for direct and indirect heart-rate measurement / Pierleoni, P.; Gambi, E.; Ricciuti, M.; Sbrollini, A.; Palma, L.; Belli, A.; Morettini, M.; Burattini, L.. - In: DATA IN BRIEF. - ISSN 2352-3409. - ELETTRONICO. - 26:104436(2019), pp. 1-4. [10.1016/j.dib.2019.104436]

Simultaneously acquired data from contactless and wearable devices for direct and indirect heart-rate measurement

Pierleoni P.
;
Gambi E.
;
Ricciuti M.;Sbrollini A.;Palma L.;Belli A.;Morettini M.;Burattini L.
2019-01-01

Abstract

The proposed dataset provides a complete set of simultaneously acquired data from contactless and wearable devices for direct and indirect heart-rate measurement. Data were acquired on a total of 20 healthy white Caucasian subjects wearing no makeup (10 males and 10 females; age: 22.50 ± 1.57 years; height: 173 ± 10 cm; weight: 62.80 ± 9.52 kg) and consisted of: i) videos of the subject's face acquired by a RGB-D (Red, Green, Blue and Depth) camera (Microsoft Kinect v2), which is a contactless device; ii) electrocardiographic (ECG) recordings acquired by a clinical Holter ECG recorder (Global Instrumentation's M12R Holter), which is a wearable device; and iii) heart-rate measurements acquired from a commercial smartwatch (Moto 360 smartwatch by Motorola), which is also a wearable device. ECG recordings were processed to extract the R-peaks position and obtain a reference indirect measurement of the heart rate. A direct measurement of the heart rate was provided by the commercial smartwatch. The dataset here presented could be useful to develop new algorithms for heart-rate detection from contactless devices and to validate contactless heart-rate estimation in comparison to reference heart rate from clinical wearable devices and to heart rate from commercial wearable devices.
2019
File in questo prodotto:
Non ci sono file associati a questo prodotto.

I documenti in IRIS sono protetti da copyright e tutti i diritti sono riservati, salvo diversa indicazione.

Utilizza questo identificativo per citare o creare un link a questo documento: https://hdl.handle.net/11566/269568
 Attenzione

Attenzione! I dati visualizzati non sono stati sottoposti a validazione da parte dell'ateneo

Citazioni
  • ???jsp.display-item.citation.pmc??? 1
  • Scopus 4
  • ???jsp.display-item.citation.isi??? 3
social impact