BACKGROUND: The objective of the study was to identify the parameter(s) of cardiopulmonary exercise testing (CPET) that can detect exercise-induced myocardial ischaemia (EIMI), and to determine its diagnostic accuracy for identifying patients with coronary artery disease (CAD). METHODS AND RESULTS: We prospectively studied 202 consecutive patients (173 men, 29 women, mean age 55.7+/-10.8 years) with documented CAD. All patients underwent an incremental exercise stress testing (ECG-St) with breath-by-breath gas exchange analysis, followed by a 2-day stress/rest gated SPECT myocardial scintigraphy (GSMS) as the gold standard for ischaemia detection. ROC analysis selected a two-variable model-O(2)pulse flattening duration, calculated from the onset of myocardial ischaemia to peak exercise, and deltaVO(2)/deltawork rate slope-to predict EIMI by CPET. GSMS identified 140 patients with reversible myocardial defects, with a Summed Difference Score (SDS) of 9.7+/-2.8, and excluded EIMI in 62 (SDS 1.3+/-1.6). ECG-St had low sensitivity (46%) and specificity (66%) to diagnose EIMI as compared with CPET (87% and 74%, respectively). CONCLUSIONS: The addition of gas exchange analysis improves the diagnostic accuracy of standard ECG stress testing in identifying EIMI. A two-variable model based on O(2)pulse flattening duration and deltaVO(2)/deltawork rate slope had the highest predictive ability to identify EIMI.

Exercise-induced myocardial ischemia detected by cardiopulmonary exercise testing / Belardinelli, R; Lacalaprice, F; Carle, Flavia; Minnucci, A; Cianci, G; Perna, Gp; Deusanio, G.. - In: EUROPEAN HEART JOURNAL. - ISSN 0195-668X. - STAMPA. - 24:14(2003), pp. 1304-1313. [10.1016/S0195-668X(03)00210-0]

Exercise-induced myocardial ischemia detected by cardiopulmonary exercise testing

CARLE, Flavia;
2003-01-01

Abstract

BACKGROUND: The objective of the study was to identify the parameter(s) of cardiopulmonary exercise testing (CPET) that can detect exercise-induced myocardial ischaemia (EIMI), and to determine its diagnostic accuracy for identifying patients with coronary artery disease (CAD). METHODS AND RESULTS: We prospectively studied 202 consecutive patients (173 men, 29 women, mean age 55.7+/-10.8 years) with documented CAD. All patients underwent an incremental exercise stress testing (ECG-St) with breath-by-breath gas exchange analysis, followed by a 2-day stress/rest gated SPECT myocardial scintigraphy (GSMS) as the gold standard for ischaemia detection. ROC analysis selected a two-variable model-O(2)pulse flattening duration, calculated from the onset of myocardial ischaemia to peak exercise, and deltaVO(2)/deltawork rate slope-to predict EIMI by CPET. GSMS identified 140 patients with reversible myocardial defects, with a Summed Difference Score (SDS) of 9.7+/-2.8, and excluded EIMI in 62 (SDS 1.3+/-1.6). ECG-St had low sensitivity (46%) and specificity (66%) to diagnose EIMI as compared with CPET (87% and 74%, respectively). CONCLUSIONS: The addition of gas exchange analysis improves the diagnostic accuracy of standard ECG stress testing in identifying EIMI. A two-variable model based on O(2)pulse flattening duration and deltaVO(2)/deltawork rate slope had the highest predictive ability to identify EIMI.
2003
File in questo prodotto:
Non ci sono file associati a questo prodotto.

I documenti in IRIS sono protetti da copyright e tutti i diritti sono riservati, salvo diversa indicazione.

Utilizza questo identificativo per citare o creare un link a questo documento: https://hdl.handle.net/11566/26477
 Attenzione

Attenzione! I dati visualizzati non sono stati sottoposti a validazione da parte dell'ateneo

Citazioni
  • ???jsp.display-item.citation.pmc??? 55
  • Scopus 213
  • ???jsp.display-item.citation.isi??? 184
social impact