Bioimpedance measurements represent an advantageous method to evaluate the physio-pathological conditions of biological tissues and their use is spreading in different application fields, from the evaluation of body composition to the vital signs monitoring, passing through the individuation of cancer tissues and the detection of different substances (e.g. glucose measurements in people affected by diabetes). In fact, tissues electric properties vary with their conditions; for example, electrical conductivity increases when there is an inflammatory process, because of the presence of oedema, hyperaemia and infiltration. Inflammatory phenomena are frequent in dentistry, in diseases like periodontitis and peri-implantitis; however, at present the diagnosis is mainly done with the naked eye, by observing the gingiva redness and swelling. The aim of this work is to prove the feasibility of the inflammation detection by means of bioimpedance measurements. Both numerical simulations and preliminary experimental measurements provide significant outcomes in differentiating between healthy and inflamed tissues. Percentage differences in the impedance modulus equal to 4-20% (numerical simulations) and 35-56% (experimental measurements), respectively, depending on the considered conditions (e.g. electrodes characteristics and inflammation severity), were found. Such measure could be integrated in electromedical devices designed, for example, for the therapy of peri-implantitis, in order to personalise the therapeutic dose in terms of intensity and duration and focusing it on the impaired area, minimising the effects on the surrounding tissues.

Bioimpedance measurements in dentistry to detect inflammation: numerical modelling and experimental results / Cosoli, Gloria; Scalise, Lorenzo; Tricarico, Gerardo; Russo, Paola; Cerri, Graziano. - In: PHYSIOLOGICAL MEASUREMENT. - ISSN 0967-3334. - ELETTRONICO. - 38:6(2017), pp. 1145-1157. [10.1088/1361-6579/aa5c7b]

Bioimpedance measurements in dentistry to detect inflammation: numerical modelling and experimental results

Cosoli, Gloria;SCALISE, Lorenzo;RUSSO, Paola;CERRI, GRAZIANO
2017-01-01

Abstract

Bioimpedance measurements represent an advantageous method to evaluate the physio-pathological conditions of biological tissues and their use is spreading in different application fields, from the evaluation of body composition to the vital signs monitoring, passing through the individuation of cancer tissues and the detection of different substances (e.g. glucose measurements in people affected by diabetes). In fact, tissues electric properties vary with their conditions; for example, electrical conductivity increases when there is an inflammatory process, because of the presence of oedema, hyperaemia and infiltration. Inflammatory phenomena are frequent in dentistry, in diseases like periodontitis and peri-implantitis; however, at present the diagnosis is mainly done with the naked eye, by observing the gingiva redness and swelling. The aim of this work is to prove the feasibility of the inflammation detection by means of bioimpedance measurements. Both numerical simulations and preliminary experimental measurements provide significant outcomes in differentiating between healthy and inflamed tissues. Percentage differences in the impedance modulus equal to 4-20% (numerical simulations) and 35-56% (experimental measurements), respectively, depending on the considered conditions (e.g. electrodes characteristics and inflammation severity), were found. Such measure could be integrated in electromedical devices designed, for example, for the therapy of peri-implantitis, in order to personalise the therapeutic dose in terms of intensity and duration and focusing it on the impaired area, minimising the effects on the surrounding tissues.
2017
File in questo prodotto:
Non ci sono file associati a questo prodotto.

I documenti in IRIS sono protetti da copyright e tutti i diritti sono riservati, salvo diversa indicazione.

Utilizza questo identificativo per citare o creare un link a questo documento: https://hdl.handle.net/11566/245184
 Attenzione

Attenzione! I dati visualizzati non sono stati sottoposti a validazione da parte dell'ateneo

Citazioni
  • ???jsp.display-item.citation.pmc??? 2
  • Scopus 6
  • ???jsp.display-item.citation.isi??? 6
social impact